hl7:author
|
|
1 … * |
R |
At least one author MUST be declared. |
(CH_LREP_AUTO) |
hl7:functionCode
|
CE |
0 … 1 |
C |
At least one of the listed authors must be a laboratory specialist. |
(CH_LREP_AUTO) |
@displayName
|
st |
1 … 1 |
F |
Medical and pathology laboratory technicians |
@codeSystemName
|
st |
1 … 1 |
F |
ISCO-08 |
@codeSystem
|
oid |
1 … 1 |
F |
2.16.840.1.113883.2.9.6.2.7 |
@code
|
cs |
1 … 1 |
F |
3212 |
hl7:time
|
TS.CH.TZ |
1 … 1 |
R |
Date and time of the laboratory report creation. |
(CH_LREP_AUTO) |
hl7:assignedAuthor
|
|
1 … 1 |
R |
The author CAN be a person or a software module. |
(CH_LREP_AUTO) |
|
Schematron assert |
role |
error
|
|
|
test |
not(assignedAuthoringDevice/softwareName) or (representedOrganization) |
|
|
Message |
For device authors the element representedOrganization is required. |
|
|
Schematron assert |
role |
error
|
|
|
test |
(telecom[@use='PUB' and starts-with(@value,'tel:+']) and (telecom[@use='PUB' and starts-with(@value,'mailto:']) |
|
|
Message |
A public telephone number in the international format and a public eMail address are
required. |
|
|
Schematron assert |
role |
error
|
|
|
test |
(addr[@use='PUB']) |
|
|
Message |
A public address is required. |
|
hl7:id
|
II |
1 … * |
R |
The specification of GS1 GLN is required. If it is not (yet) known, this must be declared
using nullFlavor.
For persons whose personal GLN must be specified.
For software modules the GLN of the laboratory MUST be specified.
|
(CH_LREP_AUTO) |
@nullFlavor
|
cs |
0 … 1 |
F |
NAV |
|
Temporarily unknown, will be filled later. |
@extension
|
st |
0 … 1 |
|
The GS1 GLN. |
@root
|
cs |
0 … 1 |
F |
2.51.1.3 |
|
OID for GS1 GLN. |
|
Schematron assert |
role |
error
|
|
|
test |
(@root='2.51.1.3' and @extension) or (@nullFlavor='NAV') |
|
|
Message |
Either the GS1 GLN or nullFlavor='NAV' is required |
|
hl7:addr
|
AD |
1 … * |
R |
Address of the laboratory. |
(CH_LREP_AUTO) |
hl7:telecom
|
TEL |
1 … * |
R |
Means of communication of the laboratory (phone, eMail, ...). |
(CH_LREP_AUTO) |
Choice |
0 … 1 |
|
Elements to choose from:
|
hl7:assignedPerson
|
|
|
|
All persons and organizations, MUST according to XD-LAB contain name, addr and telecom. Contains 2.16.756.5.30.1.1.10.9.18 Person with Name (DYNAMIC)
|
(CH_LREP_AUTO) |
hl7:assignedAuthoringDevice
|
|
|
|
The name of the software module MUST be specified if the author is a software module. Contains 2.16.756.5.30.1.1.1.1.3.9.1.10.9.2 Device for LIS (DYNAMIC)
|
(CH_LREP_AUTO) |
hl7:representedOrganization
|
|
0 … 1 |
|
All persons and organizations, MUST according to XD-LAB contain name, addr and telecom. Contains 2.16.756.5.30.1.1.10.9.19 Organization with Name, Addr, Telecom (DYNAMIC)
|
(CH_LREP_AUTO) |