Back To Index  <<  Back To Templates

ref Template  Specimen Type

Id 2.16.756.5.30.1.1.10.4.27
ref
ch-palm-
Effective Date 2017‑06‑21
Status pending Under pre-publication review Version Label 2017
Name chpalm_entry_SpecimenType Display Name Specimen Type
Description Specimen Type.
Context Pathname
Label CH‑PALM
Classification CDA Entry Level Template
Open/Closed Open (other than defined elements are allowed)
Used by / Uses
Used by 0 transactions and 11 templates, Uses 0 templates
Used by as Name Version
2.16.756.5.30.1.1.10.4.24 Containment pending Specimen collection - participant Containment (2017) 2017‑06‑21
2.16.756.5.30.1.1.10.4.11 link pending Specimen Collection (2017) 2017‑06‑21
notice Circular reference found with 2.16.756.5.30.1.1.10.4.11, please check
2.16.756.5.30.1.1.10.4.17 link pending Laboratory Isolate Organizer (2017) 2017‑06‑21
2.16.756.5.30.1.1.10.4.4 link pending Laboratory Report Data Processing Entry (2017) 2017‑06‑21
2.16.756.5.30.1.1.10.3.3 link pending Laboratory Speciality Section - coded (2017) 2017‑06‑21
2.16.756.5.30.1.1.10.1.10 link pending General Laboratory Report (2018) 2018‑04‑19
2.16.756.5.30.1.1.10.3.5 link pending Laboratory Report Item Section - coded (2017) 2017‑06‑21
2.16.756.5.30.1.1.10.4.19 link pending Laboratory Battery Organizer (2017) 2017‑06‑21
2.16.756.5.30.1.1.10.4.3 link pending Laboratory Observation (2017) 2017‑06‑21
2.16.756.5.30.1.1.10.4.85 link pending Laboratory Isolate Organizer - Pathogen Detection (2018) 2018‑04‑19
2.16.756.5.30.1.1.10.4.87 link pending Laboratory Battery Organizer - Antibiogram (2018) 2018‑04‑19
Relationship Specialization: template 2.16.840.1.113883.10.12.313 (2005‑09‑07)
Example
Example
<code code="LOINC" codeSystem="2.16.756.5.30.2.1.1.10" codeSystemName="CDA-CH Material"/>
Item DT Card Conf Description Label
Choice 0 … * Elements to choose from:
  • hl7:code[(@code='LOINC' and @codeSystem='2.16.756.5.30.2.1.1.10')]
  • hl7:code
hl7:code
CE 0 … 1 R IHE XD-LAB requires coding of the specimen. However, since the laboratory results have to be coded with LOINC, the specimen is already defined via the 'System' axis of LOINC. Therefore the following, fixed code CAN be used for laboratory reports in Switzerland. CH-PALM
@code
cs 1 … 1 F LOINC
@codeSystem
oid 1 … 1 F 2.16.756.5.30.2.1.1.10
@codeSystemName
st 1 … 1 F CDA-CH Material
@displayName
st 0 NP NP/not present
hl7:code
CD 0 … 1 R IF the coding of the specimen with LOINC's 'System' axis is insufficient, a precise code CAN be used. The use of SNOMED-CT is recommended. CH-PALM
@code
cs 1 … 1 R The code MUST be specified.
@codeSystem
oid 1 … 1 R The OID of the code system MUST be specified.
@codeSystemName
st 1 … 1 R The name of the code system MUST be specified for tracking purposes. However, processing is NOT ALLOWED.
@displayName
st 1 … 1 R The displayName of the code MUST be specified for tracking purposes. However, processing is NOT ALLOWED. Instead, a processing system is to display a user readable language translation of the code from the value set.
hl7:qualifier
CR 0 … * A precision of the code CAN be specified using a qualifier. Not further specified. CH-PALM
hl7:name
CV 0 … * CH-PALM
hl7:value
CD 0 … * CH-PALM