hl7:organizer
|
|
|
|
Coding of an antibiogram. This organizer MUST be placed as a component within a Pathogen
Detection Laboratory Isolate Organizer.
|
CDA-LREP |
@classCode
|
cs |
1 … 1 |
F |
BATTERY |
@moodCode
|
cs |
1 … 1 |
F |
EVN |
hl7:templateId
|
II |
1 … 1 |
M |
|
CDA-LREP |
@root
|
uid |
1 … 1 |
F |
2.16.756.5.30.1.1.10.4.87 |
hl7:templateId
|
II |
1 … 1 |
M |
|
CDA-LREP |
@root
|
uid |
1 … 1 |
F |
2.16.756.5.30.1.1.10.4.19 |
hl7:templateId
|
II |
1 … 1 |
M |
|
CDA-LREP |
@root
|
uid |
1 … 1 |
F |
1.3.6.1.4.1.19376.1.3.1.4 |
hl7:id
|
II |
0 … 1 |
|
An ID for this item MAY be filled for traceability. |
CDA-LREP |
@root
|
uid |
1 … 1 |
R |
MUST contain the OID of the system that issued the ID. OIDs of code systems, which
are published in the public OID registry for the Swiss health care system (oid.refdata.ch)
are REQUIRED. Others are NOT ALLOWED.
|
@extension
|
st |
0 … 1 |
|
Contains the ID itself. The ID MUST be unique within the system that issued the ID. |
hl7:code
|
CD |
0 … 1 |
|
The antibiogram MUST be declared using the LOINC code 29576-6 "Bacterial susceptibility
panel".
|
CDA-LREP |
@code
|
cs |
1 … 1 |
F |
29576-6 |
@codeSystem
|
oid |
1 … 1 |
F |
2.16.840.1.113883.6.1 |
@codeSystemName
|
st |
1 … 1 |
F |
LOINC |
@displayName
|
st |
1 … 1 |
F |
Bacterial susceptibility panel |
hl7:statusCode
|
CS |
1 … 1 |
M |
The status 'completed' means that all expected results for this results group are
present and in a final state.
The status 'aborted' means that the examinations had to be aborted. Some results MAY
be available.
|
CDA-LREP |
|
CONF |
|
hl7:effectiveTime
|
IVL_TS.CH.TZ |
1 … 1 |
R |
Timestamp or period of findings (physiologically relevant period) for all results
in this result group.
|
CDA-LREP |
@value
|
TS.CH.TZ |
0 … 1 |
|
Timestamp. Accuracy of the value: Date and time with hour and minute. If it is not
known, nullFavor='UNK' must be used.
|
hl7:low
|
TS.CH.TZ |
0 … 1 |
|
Start of the period. Accuracy of the value: Date and time with hour and minute. If
it is not known, nullFavor='UNK' must be used.
|
CDA-LREP |
|
Schematron assert |
role |
error
|
|
|
test |
string-length(@value)>11 |
|
|
Message |
A precision of date and time of day with at least hour and minute is required. |
|
hl7:high
|
TS.CH.TZ |
0 … 1 |
|
End of the period. Accuracy of the value: Date and time with hour and minute. If it
is not known, nullFavor='UNK' must be used.
|
CDA-LREP |
|
Schematron assert |
role |
error
|
|
|
test |
string-length(@value)>11 |
|
|
Message |
A precision of date and time of day with at least hour and minute is required. |
|
|
Schematron assert |
role |
error
|
|
|
test |
@nullFlavor='UNK' or @value or (hl7:low and hl7:high) |
|
|
Message |
Either the imestamp or the period of the findings MUST be declared. If it is not known,
nullFavor='UNK' must be used. |
|
Choice |
0 … 1 |
|
IF this result group is based on a specimen of a non-human material, the subject element
MUST be declared.
Elements to choose from:
|
hl7:subject
|
|
0 … 1 |
|
Contains 2.16.756.5.30.1.1.10.4.5 Non-Human Subject - subject Containment (DYNAMIC)
|
CDA-LREP |
hl7:subject
|
|
0 … 1 |
|
Contains 2.16.756.5.30.1.1.10.4.6 Human Patient with Non-Human Subject - subject Containment (DYNAMIC)
|
CDA-LREP |
hl7:performer
|
|
0 … * |
|
This CAN be used to indicate who has performed the test. This information supersedes
any information recorded at higher level. Contains 2.16.756.5.30.1.1.10.4.7 Laboratory Performer - performer Containment (DYNAMIC)
|
CDA-LREP |
hl7:author
|
|
0 … * |
|
This CAN be used to indicate who has documented the result. This information supersedes
any information recorded at higher level. Contains 2.16.756.5.30.1.1.10.9.16 Author Compilation with name, addr and telecom (DYNAMIC)
|
CDA-LREP |
Choice |
0 … * |
|
This CAN be used to identify other parties:
- Who has verified the result (AUTHEN).
- Which external laboratory has delivered the result (RESP).
- Which device (analyzer) was used to determine the result (DEV).
Elements to choose from:
|
hl7:participant
|
|
0 … * |
|
Who has verified the result (AUTHEN). This information supersedes any information
recorded at higher level. Contains 2.16.756.5.30.1.1.10.4.8 Laboratory Results Validator - participant Containment (DYNAMIC)
|
CDA-LREP |
hl7:participant
|
|
0 … * |
|
Which external laboratory has delivered the result (RESP). This information supersedes
any information recorded at higher level. Contains 2.16.756.5.30.1.1.10.4.9 Responsible Party - participant Containment (DYNAMIC)
|
CDA-LREP |
hl7:participant
|
|
0 … * |
|
Which device (analyzer) was used to determine the result (DEV). This information supersedes
any information recorded at higher level. Contains 2.16.756.5.30.1.1.10.4.10 Device - participant Containment (DYNAMIC)
|
CDA-LREP |
Choice |
0 … * |
|
For "Laboratory Observation" coding, use the filter 'property:susc class:abxbact'
on search.loinc.org (see https://search.loinc.org/searchLOINC/search.zul?query=property%3Asusc+class%3Aabxbact).
Elements to choose from:
|
hl7:component
|
|
0 … * |
|
For observation coding, use the filter 'property:susc class:abxbact' on search.loinc.org
(see https://search.loinc.org/searchLOINC/search.zul?query=property%3Asusc+class%3Aabxbact). Contains 2.16.756.5.30.1.1.10.4.3 Laboratory Observation (DYNAMIC)
|
CDA-LREP |
@typeCode
|
cs |
1 … 1 |
F |
COMP |
hl7:component
|
|
0 … * |
|
Contains 2.16.756.5.30.1.1.10.4.11 Specimen Collection (DYNAMIC)
|
CDA-LREP |
@typeCode
|
cs |
1 … 1 |
F |
COMP |
hl7:component
|
|
0 … * |
|
Contains 2.16.756.5.30.1.1.10.4.18 Multimedia Embedded Content (DYNAMIC)
|
CDA-LREP |
@typeCode
|
cs |
1 … 1 |
F |
COMP |
hl7:component
|
|
0 … * |
|
Contains 2.16.756.5.30.1.1.10.4.2 Annotation Comments (DYNAMIC)
|
CDA-LREP |
@typeCode
|
cs |
1 … 1 |
F |
COMP |
hl7:reference
|
|
0 … * |
|
This CAN be used to make reference to an external document. Contains 2.16.756.5.30.1.1.10.4.29 External document (DYNAMIC)
|
CDA-LREP |
@typeCode
|
cs |
1 … 1 |
F |
REFR |
|
Schematron assert |
role |
error
|
|
|
test |
ancestor::hl7:templateId[@root='2.16.756.5.30.1.1.10.4.85'] |
|
|
Message |
The antibiogram must be placed in a Pathogen Detection Laboratory Isolate Organizer. |
|