Back To Index  <<  Back To Templates

active Template  Non-Human Subject - recordTarget

Id 2.16.756.5.30.1.1.10.2.26
ref
ch-palm-
Effective Date 2019‑08‑20
Status active Active Version Label 2019
Name chpalm_header_RecordTargetNonHumanSubject Display Name Non-Human Subject - recordTarget
Description
ClinicalDocument/recordTarget SHALL be present and SHALL conform to the Human Patient, Non-Human Subject or Human Patient with Non-Human Subject templates defined below. There are three varieties of laboratory reports:
  • Human (patient): The document reports laboratory observations produced on specimens collected exclusively from the patient.
  • Non-Human Subject: The document reports laboratory observations produced on specimens collected from a non-human material (e.g. water, milk…) or living subject (e.g. animal).
  • Human (patient) paired with Non-Human Subject: The document reports laboratory observations produced on a non-human specimen with a relationship to a human patient, (e.g. peanut butter eaten by a patient, a ferret that bit a patient).

Non-Human Subject

When the subject of the observations in the report is a sample exclusively taken from a non-human subject, such as an animal, a lake, soil or other environmental element, the following SHALL be present.

  • <templateId root="1.3.6.1.4.1.19376.1.3.3.1.2"/> - The templateId element identifies this recordTarget as a non-human subject of laboratory testing. The templateId SHALL have root="1.3.6.1.4.1.19376.1.3.3.1.2".
  • <id/> - /patientRole/id SHALL be present and SHALL represent the id of the non-human subject.
  • <patient@nullFlavor/> - The recordTarget/patientRole SHALL have a patient sub-element and its nullFlavor SHALL be set to "OTH". This indicates that other information pertaining to the non-human subject can be found in the body of the document.
  • <structuredBody> mark-up - In addition to the elements specified in the CDA header for the non-human subject, this non-human subject SHALL be represented in a Subject element in level 3 entries in the structuredBody as described in template Non-Human Subject 1.3.6.1.4.1.19376.1.3.3.1.2.1.
Context Parent nodes of template element with id 2.16.756.5.30.1.1.10.2.26
Label IHE PalM TF3 Rev.10, 6.3.2.11.2
Classification CDA Header Level Template
Open/Closed Open (other than defined elements are allowed)
Used by / Uses
Used by 1 transaction and 1 template, Uses 0 templates
Used by as Name Version
cdachlrep-transaction-2 Transaction pending CDA-CH-LREP - General Laboratory Report (2018) 2018‑03‑06 18:38:46
2.16.756.5.30.1.1.10.1.10 Include active General Laboratory Report (2020) 2020‑06‑26
Relationship Specialization: template 2.16.840.1.113883.10.12.101 CDA recordTarget (2005‑09‑07)
ref
ad1bbr-

Specialization: template 1.3.6.1.4.1.19376.1.3.3.1.2 Non-Human Subject (2008‑08‑08)
ref
XDLAB-
Example
Non-Human Subject Example
<recordTarget typeCode="RCT">
  <templateId root="2.16.756.5.30.1.1.10.2.26"/>  <templateId root="1.3.6.1.4.1.19376.1.3.3.1.2"/>  <patientRole classCode="PAT">
    <id root="1.3.6.1.4.1.19376.1.3.4" extension="66373839"/>    <patient nullFlavor="OTH"/>  </patientRole>
</recordTarget>
Item DT Card Conf Description Label
hl7:recordTarget
1 … * R Non-Human Subject. IHE PalM TF3 Rev.10, 6.3.2.11.2
hl7:templateId
II 1 … 1 M IHE PalM TF3 Rev.10, 6.3.2.11.2
@root
uid 1 … 1 F 2.16.756.5.30.1.1.10.2.26
hl7:templateId
II 1 … 1 M IHE PalM TF3 Rev.10, 6.3.2.11.2
@root
uid 1 … 1 F 1.3.6.1.4.1.19376.1.3.3.1.2
  Schematron assert role red error  
  test //hl7:templateId[@root='1.3.6.1.4.1.19376.1.3.3.1.2.1']  
  Message In addition to the elements specified in the CDA header for the non-human subject, this non-human subject SHALL be represented in a Subject element in level 3 entries in the structuredBody.  
hl7:patientRole
1 … 1 R IHE PalM TF3 Rev.10, 6.3.2.11.2
hl7:id
II 1 … * R IHE PalM TF3 Rev.10, 6.3.2.11.2
@root
uid 1 … 1 R MUST contain the OID of the system that issued the number. OIDs of code systems, which are published in the public OID registry for the Swiss health care system (oid.refdata.ch) are REQUIRED. Others are NOT ALLOWED.
@extension
st 0 … 1   Contains the actual number of non-human material. The number MUST be unique within the system that issued the number.
hl7:patient
1 … 1 IHE PalM TF3 Rev.10, 6.3.2.11.2
@nullFlavor
cs 1 … 1 F OTH
  Indicates that there are laboratory tests for this non-human material in the CDA Body.