Back To Index  <<  Back To Templates

active Template  Laboratory Battery Organizer

Id 2.16.756.5.30.1.1.10.4.19
ref
ch-palm-
Effective Date 2019‑08‑20
Status active Active Version Label 2019
Name chpalm_entry_LaboratoryBatteryOrganizer Display Name Laboratory Battery Organizer
Description
According to IHE XD-LAB, the Laboratory Battery Organizer allows the grouping of results.
Laboratory reports MUST contain at least one result group with at least one result.
The grouping of multiple results (Observations) into multiple result groups (Laboratory Battery Organizers) is permitted.
Context Parent nodes of template element with id 2.16.756.5.30.1.1.10.4.19
Label IHE PalM TF3 Rev.10, 6.3.4.12
Classification CDA Entry Level Template
Open/Closed Open (other than defined elements are allowed)
Used by / Uses
Used by 1 transaction and 5 templates, Uses 12 templates
Used by as Name Version
cdachlrep-transaction-2 Transaction pending CDA-CH-LREP - General Laboratory Report (2018) 2018‑03‑06 18:38:46
2.16.756.5.30.1.1.10.4.118 Containment active Laboratory Report Data Processing Entry (2020) 2020‑06‑26
2.16.756.5.30.1.1.10.3.76 link active Laboratory Report Item Section - coded (2020) 2020‑06‑26
2.16.756.5.30.1.1.10.3.77 link active Laboratory Speciality Section - coded (2020) 2020‑06‑26
2.16.756.5.30.1.1.10.1.10 link active General Laboratory Report (2020) 2020‑06‑26
2.16.756.5.30.1.1.10.4.17 Containment active Laboratory Isolate Organizer (2019) 2019‑08‑20
Uses as Name Version
2.16.756.5.30.1.1.10.4.5 Containment active Non-Human Subject - subject Containment (2019) DYNAMIC
2.16.756.5.30.1.1.10.4.6 Containment active Human Patient with Non-Human Subject - subject Containment (2019) DYNAMIC
2.16.756.5.30.1.1.10.4.7 Containment active Laboratory Performer - performer Containment (2019) DYNAMIC
2.16.756.5.30.1.1.10.9.16 Containment active Author Compilation with name, addr and telecom (2020) DYNAMIC
2.16.756.5.30.1.1.10.4.8 Containment active Laboratory Results Validator - participant Containment (2019) DYNAMIC
2.16.756.5.30.1.1.10.4.9 Containment active Responsible Party - participant Containment (2019) DYNAMIC
2.16.756.5.30.1.1.10.4.10 Containment active Device - participant Containment (2020) DYNAMIC
2.16.756.5.30.1.1.10.4.11 Containment active Specimen Collection (2019) DYNAMIC
2.16.756.5.30.1.1.10.4.3 Containment active Laboratory Observation (2020) DYNAMIC
2.16.756.5.30.1.1.10.4.18 Containment active Multimedia Embedded Content (2020) DYNAMIC
2.16.756.5.30.1.1.10.4.2 Containment active Annotation Comments (2016) DYNAMIC
2.16.756.5.30.1.1.10.4.29 Containment active External document (2017) DYNAMIC
Relationship Specialization: template 2.16.840.1.113883.10.12.305 CDA Organizer (2005‑09‑07)
ref
ad1bbr-

Specialization: template 1.3.6.1.4.1.19376.1.3.1.4 Befundgruppen (Laboratory Battery Organizer) (DYNAMIC)
ref
elgabbr-
Example
Example
<organizer classCode="BATTERY" moodCode="EVN">
  <templateId root="2.16.756.5.30.1.1.10.4.19"/>  <templateId root="1.3.6.1.4.1.19376.1.3.1.4"/>  <id root="2.999" extension="your id"/>  <code displayName="displayName" codeSystemName="codeSystemName" codeSystem="1.2.3.999" code="cs"/>  <statusCode/>  <effectiveTime value="20180320134438+0100"/></organizer>
Item DT Card Conf Description Label
hl7:organizer
IHE PalM TF3 Rev.10, 6.3.4.12
@classCode
cs 1 … 1 F BATTERY
@moodCode
cs 1 … 1 F EVN
hl7:templateId
II 1 … 1 M IHE PalM TF3 Rev.10, 6.3.4.12
@root
uid 1 … 1 F 2.16.756.5.30.1.1.10.4.19
hl7:templateId
II 1 … 1 M IHE PalM TF3 Rev.10, 6.3.4.12
@root
uid 1 … 1 F 1.3.6.1.4.1.19376.1.3.1.4
hl7:id
II 0 … 1 An ID for this item MAY be filled for traceability. IHE PalM TF3 Rev.10, 6.3.4.12
@root
uid 1 … 1 R MUST contain the OID of the system that issued the ID. OIDs of code systems, which are published in the public OID registry for the Swiss health care system (oid.refdata.ch) are REQUIRED. Others are NOT ALLOWED.
@extension
st 0 … 1   Contains the ID itself. The ID MUST be unique within the system that issued the ID.
hl7:code
CD 0 … 1 If the results in this result group are associated to a codable group (e.g., LOINC Code 55429-5 for 'short blood count panel'), then the code SHOULD be specified. The code system is not further specified. LOINC (2.16.840.1.113883.6.1) or SNOMED CT (2.16.840.1.113883.6.96) codes or values from the HL7 vocabulary ObservationType (2.16.840.1.113883.1.11.16226) SHOULD be used.
If this result group contains any other results, then the code SHOULD be omitted.
IHE PalM TF3 Rev.10, 6.3.4.12
@code
cs 1 … 1 R The code MUST be specified.
@codeSystem
oid 1 … 1 R The OID of the code system MUST be specified.
@codeSystemName
st 1 … 1 R The name of the code system MUST be specified for tracking purposes. However, processing is NOT ALLOWED.
@displayName
st 1 … 1 R The displayName of the code MUST be specified for tracking purposes. However, processing is NOT ALLOWED. Instead, a processing system is to display a user readable language translation of the code from the value set.
hl7:statusCode
CS 1 … 1 M

The status 'completed' means that all expected results for this results group are present and in a final state.

The status 'aborted' means that the examinations had to be aborted. Some results MAY be available.

IHE PalM TF3 Rev.10, 6.3.4.12
  CONF
The value of @code shall be drawn from value set 1.3.6.1.4.1.19376.1.3.11.2 ActStatusAbortedCompleted (DYNAMIC)
hl7:effectiveTime
IVL_TS.CH.TZ 1 … 1 R Timestamp or period of findings (physiologically relevant period) for all results in this result group. IHE PalM TF3 Rev.10, 6.3.4.12
@value
TS.CH.TZ 0 … 1   Timestamp. Accuracy of the value: Date and time with hour and minute. If it is not known, nullFavor='UNK' must be used.
hl7:low
TS.CH.TZ 0 … 1 Start of the period. Accuracy of the value: Date and time with hour and minute. If it is not known, nullFavor='UNK' must be used. IHE PalM TF3 Rev.10, 6.3.4.12
  Schematron assert role red error  
  test string-length(@value)>11  
  Message A precision of date and time of day with at least hour and minute is required.  
hl7:high
TS.CH.TZ 0 … 1 End of the period. Accuracy of the value: Date and time with hour and minute. If it is not known, nullFavor='UNK' must be used. IHE PalM TF3 Rev.10, 6.3.4.12
  Schematron assert role red error  
  test string-length(@value)>11  
  Message A precision of date and time of day with at least hour and minute is required.  
  Schematron assert role red error  
  test @nullFlavor='UNK' or @value or (hl7:low and hl7:high)  
  Message Either the timestamp or the period of the findings MUST be declared. If it is not known, nullFavor='UNK' must be used.  
Choice 0 … 1
IF this result group is based on a specimen of a non-human material, the subject element MUST be declared.
Elements to choose from:
hl7:subject
0 … 1 Contains 2.16.756.5.30.1.1.10.4.5 Non-Human Subject - subject Containment (DYNAMIC) IHE PalM TF3 Rev.10, 6.3.4.12
hl7:subject
0 … 1 Contains 2.16.756.5.30.1.1.10.4.6 Human Patient with Non-Human Subject - subject Containment (DYNAMIC) IHE PalM TF3 Rev.10, 6.3.4.12
hl7:performer
0 … * This CAN be used to indicate who has performed the test. This information supersedes any information recorded at higher level.
Contains 2.16.756.5.30.1.1.10.4.7 Laboratory Performer - performer Containment (DYNAMIC)
IHE PalM TF3 Rev.10, 6.3.4.12
hl7:author
0 … * This CAN be used to indicate who has documented the result. This information supersedes any information recorded at higher level.
Contains 2.16.756.5.30.1.1.10.9.16 Author Compilation with name, addr and telecom (DYNAMIC)
IHE PalM TF3 Rev.10, 6.3.4.12
@typeCode
cs 1 … 1 F AUT
Choice 0 … *
This CAN be used to identify other parties:
  • Who has verified the result (AUTHEN).
  • Which external laboratory has delivered the result (RESP).
  • Which device (analyzer) was used to determine the result (DEV).
Elements to choose from:
hl7:participant
0 … * Who has verified the result (AUTHEN). This information supersedes any information recorded at higher level.
Contains 2.16.756.5.30.1.1.10.4.8 Laboratory Results Validator - participant Containment (DYNAMIC)
IHE PalM TF3 Rev.10, 6.3.4.12
hl7:participant
0 … * Which external laboratory has delivered the result (RESP). This information supersedes any information recorded at higher level.
Contains 2.16.756.5.30.1.1.10.4.9 Responsible Party - participant Containment (DYNAMIC)
IHE PalM TF3 Rev.10, 6.3.4.12
hl7:participant
0 … * Which device (analyzer) was used to determine the result (DEV). This information supersedes any information recorded at higher level.
Contains 2.16.756.5.30.1.1.10.4.10 Device - participant Containment (DYNAMIC)
IHE PalM TF3 Rev.10, 6.3.4.12
Choice 0 … * Elements to choose from:
hl7:component
0 … * Contains 2.16.756.5.30.1.1.10.4.11 Specimen Collection (DYNAMIC) IHE PalM TF3 Rev.10, 6.3.4.12
@typeCode
cs 1 … 1 F COMP
hl7:component
0 … * Contains 2.16.756.5.30.1.1.10.4.3 Laboratory Observation (DYNAMIC) IHE PalM TF3 Rev.10, 6.3.4.12
@typeCode
cs 1 … 1 F COMP
hl7:component
0 … * Contains 2.16.756.5.30.1.1.10.4.18 Multimedia Embedded Content (DYNAMIC) IHE PalM TF3 Rev.10, 6.3.4.12
@typeCode
cs 1 … 1 F COMP
hl7:component
0 … * Contains 2.16.756.5.30.1.1.10.4.2 Annotation Comments (DYNAMIC) IHE PalM TF3 Rev.10, 6.3.4.12
@typeCode
cs 1 … 1 F COMP
hl7:reference
0 … * This CAN be used to make reference to an external document.
Contains 2.16.756.5.30.1.1.10.4.29 External document (DYNAMIC)
IHE PalM TF3 Rev.10, 6.3.4.12
@typeCode
cs 1 … 1 F REFR