@typeCode
|
cs |
1 … 1 |
F |
DEV |
hl7:participantRole
|
|
1 … 1 |
R |
|
CH-PALM |
hl7:playingDevice
|
|
1 … 1 |
R |
Analyzer used to determine the result. Contains 2.16.756.5.30.1.1.10.9.21 Device Compilation with name (DYNAMIC)
|
CH-PALM |
hl7:scopingEntity
|
|
0 … 1 |
|
The test kit and its manufacturer CAN be specified. |
CH-PALM |
hl7:id
|
II |
0 … * |
|
The number of the test kit with which the result was determined CAN be specified.
Multiple numbers are PERMITTED.
|
CH-PALM |
@root
|
uid |
1 … 1 |
R |
MUST contain the OID of the system that issued the ID. OIDs of code systems, which
are published in the public OID registry for the Swiss health care system (oid.refdata.ch)
are REQUIRED. Others are NOT ALLOWED.
|
@extension
|
st |
0 … 1 |
|
Contains the number itself. The number MUST be unique within the system that issued
the number.
|
hl7:code
|
CE |
0 … 1 |
|
A code that identifies the test kit CAN be specified. If no vocabulary is available, nullFlavor='OTH' including an originalText element
MUST be used. In this case, the attributes @code, @codeSystem and @codeSystemName
are NOT ALLOWED.
|
CH-PALM |
@nullFlavor
|
cs |
0 … 1 |
F |
ASKU |
|
If no vocabulary is available, nullFlavor='ASKU' including a displayName MUST be used. |
@code
|
cs |
0 … 1 |
|
The code MUST be specified. |
@codeSystem
|
oid |
0 … 1 |
|
The OID of the code system MUST be specified. |
@codeSystemName
|
st |
0 … 1 |
|
The name of the code system MUST be specified for tracking purposes. However, processing
is NOT ALLOWED.
|
@displayName
|
st |
0 … 1 |
|
The displayName of the code MUST be specified for tracking purposes. However, processing
is NOT ALLOWED. Instead, a processing system is to display a user readable language
translation of the code from the value set.
|
Included |
0 … 1 |
C |
from 2.16.756.5.30.1.1.10.9.49 Original Text Reference (DYNAMIC) The human-readable text MUST be generated automatically from the structured information
of this element. The text element MUST contain the reference to the corresponding
text in the human readable part, ONLY.
|
hl7:originalText
|
ED |
0 … 1 |
C |
|
CDA‑CH V2 |
hl7:reference
|
TEL |
1 … 1 |
M |
The reference to the corresponding text in the human readable part must be specified
by reference to content[@ID]: reference[@value='#xxx']
|
CDA‑CH V2 |
@value
|
|
1 … 1 |
R |
Reference to the narrative part of the section in the format '#xxx', where xxx is
the ID of the corresponding
element.
|
|
Schematron assert |
role |
error
|
|
|
test |
starts-with(@value,'#') |
|
|
Message |
The @value attribute content MUST conform to the format '#xxx', where xxx is the ID
of the corresponding <content/> element. |
|
|
Variable let |
Name |
idvalue |
|
|
Value |
substring-after(@value,'#') |
|
|
Schematron assert |
role |
error
|
|
|
test |
ancestor::hl7:structuredBody//*[@ID=$idvalue] |
|
|
Message |
No narrative text found for this reference (no content element within this document
has an ID that corresponds to '<value-of select="$idvalue"/>'). |
|
|
Schematron assert |
role |
error
|
|
|
test |
parent::*/text()=ancestor::hl7:structuredBody//*[@ID=$idvalue]/text() |
|
|
Message |
The originalText content MUST be identical to the narrative text for this reference. |
|
|
Schematron assert |
role |
error
|
|
|
test |
(@code and @codeSystem) or (@nullFlavor='OTH' and hl7:originalText) |
|
|
Message |
Either a code with its code system or nullFlavor='OTH' with an originalText element
is required. |
|
hl7:desc
|
ED |
0 … 1 |
|
The manufacturer (name) of the test kit and any further information MAY be declared. |
CH-PALM |