Back To Index  <<  Back To Templates

active Template  Specimen Type

Id 2.16.756.5.30.1.1.10.4.27
ref
ch-palm-
Effective Date 2019‑08‑20
Other versions this id:
Status active Active Version Label 2020
Name chpalm_entry_SpecimenType Display Name Specimen Type
Description Specimen Type.
Label CH‑PALM
Classification CDA Entry Level Template
Open/Closed Open (other than defined elements are allowed)
Used by / Uses
Used by 3 transactions and 22 templates, Uses 0 templates
Used by as Name Version
cdachvacd-transaction-5 Transaction pending CDA-CH-VACD - Immunization Recommendation Request (2018) 2018‑04‑10 18:08:44
cdachvacd-transaction-6 Transaction pending CDA-CH-VACD - Immunization Recommendation Response (2018) 2018‑04‑10 18:09:59
cdachvacd-transaction-7 Transaction pending CDA-CH-VACD - Vaccination Record (2018) 2018‑04‑10 18:10:49
2.16.756.5.30.1.1.10.4.24 Containment active Specimen collection - participant Containment (2019) 2019‑08‑20
2.16.756.5.30.1.1.10.4.11 link active Specimen Collection (2019) 2019‑08‑20
notice Circular reference found with 2.16.756.5.30.1.1.10.4.11, please check
2.16.756.5.30.1.1.10.4.17 link rejected Laboratory Isolate Organizer (2017) 2017‑06‑21
2.16.756.5.30.1.1.10.4.19 link active Laboratory Battery Organizer (2019) 2019‑08‑20
2.16.756.5.30.1.1.10.4.17 link active Laboratory Isolate Organizer (2019) 2019‑08‑20
2.16.756.5.30.1.1.10.4.4 link active Laboratory Report Data Processing Entry (2019) 2019‑08‑20
2.16.756.5.30.1.1.10.3.3 link active Laboratory Speciality Section - coded (2019) 2019‑08‑20
2.16.756.5.30.1.1.10.1.17 link active Immunization Recommendation Request (2020) 2020‑06‑26
2.16.756.5.30.1.1.10.1.17 link rejected Immunization Recommendation Request (2018) 2018‑04‑19
2.16.756.5.30.1.1.10.1.18 link active Immunization Recommendation Response (2020) 2020‑06‑26
2.16.756.5.30.1.1.10.1.18 link rejected Immunization Recommendation Response (2018) 2018‑04‑19
2.16.756.5.30.1.1.10.1.19 link active Vaccination Record (2020) 2020‑06‑26
2.16.756.5.30.1.1.10.1.19 link rejected Vaccination Record (2018) 2018‑04‑19
2.16.756.5.30.1.1.10.3.3 link rejected Laboratory Speciality Section - coded (2017) 2017‑06‑21
2.16.756.5.30.1.1.10.3.5 link active Laboratory Report Item Section - coded (2019) 2019‑08‑20
2.16.756.5.30.1.1.10.3.5 link rejected Laboratory Report Item Section - coded (2017) 2017‑06‑21
2.16.756.5.30.1.1.10.4.4 link rejected Laboratory Report Data Processing Entry (2017) 2017‑06‑21
2.16.756.5.30.1.1.10.4.19 link rejected Laboratory Battery Organizer (2017) 2017‑06‑21
2.16.756.5.30.1.1.10.4.3 link active Laboratory Observation (2020) 2019‑08‑20
2.16.756.5.30.1.1.10.4.11 link rejected Specimen Collection (2017) 2017‑06‑21
notice Circular reference found with 2.16.756.5.30.1.1.10.4.11, please check
2.16.756.5.30.1.1.10.4.3 link rejected Laboratory Observation (2017) 2017‑06‑21
2.16.756.5.30.1.1.10.4.24 Containment rejected Specimen collection - participant Containment (2017) 2017‑06‑21
Relationship Specialization: template 2.16.840.1.113883.10.12.313 CDA PlayingEntity (2005‑09‑07)
ref
ad1bbr-
Example
Example
<code code="LOINC" codeSystem="2.16.756.5.30.2.1.1.10" codeSystemName="CDA-CH Material"/>
Item DT Card Conf Description Label
Choice 0 … * Elements to choose from:
  • hl7:code[(@code = 'LOINC' and @codeSystem = '2.16.756.5.30.2.1.1.10')]
  • hl7:code
hl7:code
CE 0 … 1 R IHE XD-LAB requires coding of the specimen. However, since the laboratory results have to be coded with LOINC, the specimen is already defined via the 'System' axis of LOINC. Therefore the following, fixed code CAN be used for laboratory reports in Switzerland. CH-PALM
@code
cs 1 … 1 F LOINC
@codeSystem
oid 1 … 1 F 2.16.756.5.30.2.1.1.10
@codeSystemName
st 1 … 1 F CDA-CH Material
@displayName
st 0 NP NP/not present
hl7:code
CD 0 … 1 R IF the coding of the specimen with LOINC's 'System' axis is insufficient, a precise code CAN be used. The use of SNOMED-CT is recommended. CH-PALM
@code
cs 1 … 1 R The code MUST be specified.
@codeSystem
oid 1 … 1 R The OID of the code system MUST be specified.
@codeSystemName
st 1 … 1 R The name of the code system MUST be specified for tracking purposes. However, processing is NOT ALLOWED.
@displayName
st 1 … 1 R The displayName of the code MUST be specified for tracking purposes. However, processing is NOT ALLOWED. Instead, a processing system is to display a user readable language translation of the code from the value set.
hl7:qualifier
CR 0 … * A precision of the code CAN be specified using a qualifier. Not further specified. CH-PALM
hl7:name
CV 0 … * CH-PALM
hl7:value
CD 0 … * CH-PALM