hl7:procedure
|
|
|
|
|
IHE PalM TF3 Rev.8, 6.3.4.5 |
@classCode
|
cs |
1 … 1 |
F |
PROC |
@moodCode
|
cs |
1 … 1 |
F |
EVN |
hl7:templateId
|
II |
1 … 1 |
M |
|
IHE PalM TF3 Rev.8, 6.3.4.5 |
@root
|
uid |
1 … 1 |
F |
1.3.6.1.4.1.19376.1.3.1.2 |
hl7:templateId
|
II |
1 … 1 |
M |
|
IHE PalM TF3 Rev.8, 6.3.4.5 |
@root
|
uid |
1 … 1 |
F |
2.16.756.5.30.1.1.10.4.11 |
hl7:id
|
II |
0 … 1 |
|
An ID for this item MAY be filled for traceability. |
IHE PalM TF3 Rev.8, 6.3.4.5 |
@root
|
uid |
1 … 1 |
R |
MUST contain the OID of the system that issued the ID. OIDs of code systems, which
are published in the public OID registry for the Swiss health care system (oid.refdata.ch)
are REQUIRED. Others are NOT ALLOWED.
|
@extension
|
st |
0 … 1 |
|
Contains the ID itself. The ID MUST be unique within the system that issued the ID. |
hl7:code
|
CD |
1 … 1 |
M |
LOINC specimen collection code. |
IHE PalM TF3 Rev.8, 6.3.4.5 |
@code
|
cs |
1 … 1 |
F |
33882-2 |
@codeSystem
|
oid |
1 … 1 |
F |
2.16.840.1.113883.6.1 |
@codeSystemName
|
st |
1 … 1 |
F |
LOINC |
@displayName
|
st |
1 … 1 |
F |
Collection date of Unspecified specimen |
Included |
1 … 1 |
|
from 2.16.756.5.30.1.1.10.9.14 Narrative Text Reference (DYNAMIC) The human-readable text MUST be generated automatically from the structured information
of this element. The text element MUST contain the reference to the corresponding
text in the human readable part, ONLY.
|
hl7:text
|
ED |
1 … 1 |
M |
|
CDA‑CH V2 |
hl7:reference
|
TEL |
1 … 1 |
M |
The reference to the corresponding text in the human readable part must be specified
by reference to content[@ID]: reference[@value='#xxx']
|
CDA‑CH V2 |
@value
|
|
1 … 1 |
R |
Reference to the narrative part of the section in the format '#xxx', where xxx is
the ID of the corresponding
element.
|
|
Schematron assert |
role |
error
|
|
|
test |
starts-with(@value,'#') |
|
|
Message |
The @value attribute content MUST conform to the format '#xxx', where xxx is the ID
of the corresponding <content/> element. |
|
|
Variable let |
Name |
idvalue |
|
|
Value |
substring-after(@value,'#') |
|
|
Schematron assert |
role |
error
|
|
|
test |
ancestor::hl7:structuredBody//*[@ID=$idvalue] |
|
|
Message |
No narrative text found for this reference (no content element within this document
has an ID that corresponds to '<value-of select="$idvalue"/>'). |
|
hl7:effectiveTime
|
IVL_TS.CH.TZ |
1 … 1 |
|
Timestamp (e.g., for simple blood sampling) or period (e.g., 24 hour urine test)
of the specimen collection or specimen creation.
- Timestamp: Is declared using @value. Minimum accuracy of the value: Date (the time
of the day is OPTIONAL).
- Period: Is declared using low/@value and high/@value. Accuracy of the value: Date
and time with hour and minute.
|
IHE PalM TF3 Rev.8, 6.3.4.5 |
@nullFlavor
|
cs |
0 … 1 |
F |
UNK |
|
If the moment in time of the sampling is not known, nullFlavor='UNK' MUST be used. |
|
Schematron assert |
role |
error
|
|
|
test |
(@nullFlavor='UNK') or (string-length(@value)>7) or ((hl7:low/@nullFlavor='UNK' or
string-length(hl7:low/@value)>7) and (hl7:high/@nullFlavor='UNK' or string-length(hl7:high/@value)>7))
|
|
|
Message |
A precision of day is required. |
|
hl7:targetSiteCode
|
CD |
0 … 1 |
|
This CAN be used to indicate the anatomical position of the specimen collection.
This is particularly relevant in microbiology (e.g., when the sample was removed with
a swab from the left foot). The HL7 vocabulary ActSite contains anatomical locations
of organisms that may be at the center of the action.
|
IHE PalM TF3 Rev.8, 6.3.4.5 |
@code
|
cs |
1 … 1 |
R |
The code MUST be specified. |
@codeSystem
|
oid |
1 … 1 |
F |
2.16.840.1.113883.5.1052 |
@codeSystemName
|
st |
1 … 1 |
F |
ActSite |
@displayName
|
st |
1 … 1 |
R |
The displayName of the code MUST be specified for tracking purposes. However, processing
is NOT ALLOWED. Instead, a processing system is to display a user readable language
translation of the code from the value set.
|
hl7:performer
|
|
0 … 1 |
|
This can be used to specify who performed the specimen collection. Contains 2.16.756.5.30.1.1.10.4.7 Laboratory Performer - performer Containment (DYNAMIC)
|
IHE PalM TF3 Rev.8, 6.3.4.5 |
|
where [hl7:templateId [@root = '2.16.756.5.30.1.1.10.4.7'] and hl7:templateId [@root =
'1.3.6.1.4.1.19376.1.3.3.1.7']] |
|
|
hl7:participant
|
|
1 … 1 |
M |
The information on the specimen MUST be declared. Contains 2.16.756.5.30.1.1.10.4.24 Specimen collection - participant Containment (DYNAMIC)
|
IHE PalM TF3 Rev.8, 6.3.4.5 |
|
where [not(@nullFlavor)] [@typeCode = 'PRD'] [hl7:participantRole [@classCode = 'SPEC']] |
|
|
hl7:entryRelationship
|
|
0 … 1 |
|
This MAY be used to indicate when the sample has arrived at the laboratory. Contains 2.16.756.5.30.1.1.10.4.12 Specimen Received (DYNAMIC)
|
IHE PalM TF3 Rev.8, 6.3.4.5 |
|
where [hl7:act [hl7:templateId [@root = '1.3.6.1.4.1.19376.1.3.1.3'] and hl7:templateId
[@root = '2.16.756.5.30.1.1.10.4.12']]] |
|
|
@typeCode
|
cs |
1 … 1 |
F |
COMP |
hl7:entryRelationship
|
|
0 … * |
|
This MAY be used to indicate observations of the specimen collection. This allows
to provide information to the laboratory, that are important e.g. for a 24-hour urine
test:
- Collection period for 24 hour urine test: @code='13362-9' (Collection duration of
Urine), @value='24', @unit='h'
- Collected volume (urine quantity): @code='19153-6' (Volume in Urine collected for
unspecified duration), @value: urine quantity, @unit: UCUM unit of urine quantity
(e.g. ml, dl or l)
Contains 2.16.756.5.30.1.1.10.4.3 Laboratory Observation (DYNAMIC)
|
IHE PalM TF3 Rev.8, 6.3.4.5 |
|
where [hl7:observation [hl7:templateId [@root = '1.3.6.1.4.1.19376.1.3.1.6'] and hl7:templateId
[@root = '2.16.756.5.30.1.1.10.4.3']]] |
|
|
@typeCode
|
cs |
1 … 1 |
F |
COMP |