Back To Index  <<  Back To Templates

ref Template  Device Compilation with name

Id 2.16.756.5.30.1.1.10.9.21
ref
hl7chcda-
Effective Date 2018‑04‑18
Status active Active Version Label 2017
Name cdach_other_DeviceCompilationWithName Display Name Device Compilation with name
Description
Reusable template wherever a device with required name is used in a CDA-CH V2 document. CDA-CH V2 derivatives, i.e. Swiss exchange formats MAY use this template by either reference or specialisation.
A device is either a physical device (e.g. analyzer with which laboratory results are determined) or a software (e.g. laboratory information system, in which laboratory results are documented).
Context Pathname
Label CDA‑CH V2
Classification Template type not specified
Open/Closed Open (other than defined elements are allowed)
Used by / Uses
Used by 0 transactions and 21 templates, Uses 0 templates
Used by as Name Version
2.16.756.5.30.1.1.10.2.59 Containment pending Author (2018) 2018‑04‑19
2.16.756.5.30.1.1.10.1.10 link pending General Laboratory Report (2018) 2018‑04‑19
2.16.756.5.30.1.1.10.4.10 Containment pending Device - participant Containment (2017) 2017‑06‑21
2.16.756.5.30.1.1.10.4.17 link pending Laboratory Isolate Organizer (2017) 2017‑06‑21
2.16.756.5.30.1.1.10.4.4 link draft Laboratory Report Data Processing Entry (2017) 2018‑07‑14 12:26:38
2.16.756.5.30.1.1.10.3.3 link pending Laboratory Speciality Section - coded (2017) 2017‑06‑21
2.16.756.5.30.1.1.10.3.5 link pending Laboratory Report Item Section - coded (2017) 2017‑06‑21
2.16.756.5.30.1.1.10.4.4 link pending Laboratory Report Data Processing Entry (2017) 2017‑06‑21
2.16.756.5.30.1.1.10.4.19 link pending Laboratory Battery Organizer (2017) 2017‑06‑21
2.16.756.5.30.1.1.10.4.3 link pending Laboratory Observation (2017) 2017‑06‑21
notice Circular reference found with 2.16.756.5.30.1.1.10.4.3, please check
2.16.756.5.30.1.1.10.4.11 link pending Specimen Collection (2017) 2017‑06‑21
2.16.756.5.30.1.1.10.4.85 link pending Laboratory Isolate Organizer - Pathogen Detection (2018) 2018‑04‑19
2.16.756.5.30.1.1.10.4.87 link pending Laboratory Battery Organizer - Antibiogram (2018) 2018‑04‑19
2.16.756.5.30.1.1.10.9.16 Containment active Author Compilation with name, addr and telecom (2017) 2018‑04‑18
2.16.756.5.30.1.1.10.4.2 link pending Annotation Comments (2016) 2016‑11‑11
2.16.756.5.30.1.1.10.9.48 Containment active Author Compilation with name (2017) 2018‑04‑18
2.16.756.5.30.1.1.10.4.102 link pending Pregnancy Observation Delivery Date (2018) 2018‑04‑19
2.16.756.5.30.1.1.10.3.53 link pending Current Pregnancy Section - coded (2018) 2018‑04‑19
2.16.756.5.30.1.1.10.4.84 link pending Gestational Age At Birth (2018) 2018‑04‑19
2.16.756.5.30.1.1.10.3.46 link pending Other Relevant Observations Section - coded (2018) 2018‑04‑19
2.16.756.5.30.1.1.10.4.92 link pending Pregnancy Observation Entry (2016) 2016‑11‑11
Relationship Specialization: template 2.16.840.1.113883.10.12.315 (2005‑09‑07)
Example
Software
<manufacturerModelName>4.0</manufacturerModelName><softwareName>New generation KIS</softwareName>
Example
Physical device
<manufacturerModelName>w872</manufacturerModelName><softwareName>Pipette laboratory analyzer</softwareName>
Item DT Card Conf Description Label
hl7:manufacturerModelName
SC 0 … 1 The model name of the device MAY be declared. CDA‑CH V2
hl7:softwareName
SC 1 … 1 R The name of the device MUST be declared.
Note: Altough this element is called softwareName, it contains also the name of physical devices (e.g. laboratory analyzer).
CDA‑CH V2